Analysis of Temperature Fields in Angular Velocity Measurement Units on Fiber-Optic Gyros

Статья подготовлена сотрудниками: к.т.н. Голиков А.В. . д.т.н., проф. Панкратов В.М..
на базе: Лаборатория анализа и синтеза динамических систем в прецизионной механике.


Анотация

Mathematical models of 3D transient temperature fields in angular velocity measurement unit (AVMU) and constituent fiber-optic gyros both in basic structure and in the structure with reversible heat control system (HCS) are developed and implemented. Comparative analysis of temperature fields under complex temperature effects is conducted. Efficiency of reversible double-circuit HCS application is assessed.

DOI 10.1134/S2075108718020050

Ссылка на статью

Цитировать эту статью:

A. V. Golikov, V. M. Pankratov, and M. V. Efremov Analysis of Temperature Fields in Angular Velocity Measurement Units on Fiber-Optic Gyros // Gyroscopy and Navigation, 2018, Vol. 9, No. 2, pp. 116–123. © Pleiades Publishing, Ltd., 2018